0086-531-88190005
CO2 Laser Power SupplyCO2 Laser TubeMedical and Beauty Power SupplySemiconductor Power SupplyXenon Lamp Power SupplyLaser MachineLaser Machine Spare Parts
150W 350W Xenon Lamp Power Supply LCX150 LCX350
Source:SHANDONG LASER SOURCE    Release time:2019-09-28

150W 350W Xenon Lamp Power Supply LCX150 LCX350

Main features

1.Real-time voltage and current digital display, easy to monitor
2. Wide range of input voltage, can be used for any country.
3. Current can be adjusted between 4-7.5A.
4. Excellent efficiency and over current, overload protection and open circuit protection.
5. Integrated design of constant current and trigger module.

Connectors

1.input and output connectors

input and output connectors

Instructions:
① AC input —— L、N connects 90~260V 50/60Hz AC,PE connects ground
② Output —— connects short arc xenon lamp; LAMP- connects cathode of xenon lamp, LAMP+ connects anode of xenon lamp.

2.Screen and buttons

Screen and buttons

Instructions:
① Screen ——shows company information,trigger mode,output voltage,current,web,etc.
② “SET” ——set “Trigger” model and “SetPoint” mode;
③ “UP” ——increase set current or switch “Auto” and “Manual” trigger mode;
④  “ON/OFF” ——under “Auto” mode, control the output and stop of power supply;
⑤ “Down” ——reduce set current or switch “Auto” and “Manual” trigger mode;
⑥ Company Name

Screen information and buttons

1. Information on screen
Trigger:trigger mode, “Auto” means triggering the lamp automatically when power on,”Manual” means triggering lamp manually; can set by buttons, when the mode is reset, it’s only valid after restarting power;
Voltage:working voltage after lighting the lamp;
Current:working current after lighting the lamp;
SetPoint:set current, can be changed by buttons;
“Auto” and “Manual” interfaces are as follows:
  

When input voltage is less than 90VAC the screen will show “Input Under Voltage”, the power supply will stop output. And when user does not turn off the power, even the input voltage returns normal it will still show “Input Under Voltage”. When input voltage is more than 264VAC, the screen will show “Input Over Voltage”, and the power supply will stop output. And when user does not turn off the power, even the input voltage returns normal it will still show “Input Over Voltage”. When output current is more than 9A the screen will show “Output Over Current” and power supply will stop output, the fault information is like this:

2. Buttons control
“SET” ——press “SET for 1.5sec and enter set mode, touch it softly then it will switch “Trigger” and “SetPoint”, if 5 sec no operation then it will save the setting automatically.. Press the button for 1.5sec it will cancel the setting and does not save the data.;
“UP” ——press it then the current will increase by 0.1A;under trigger mode it can also switch trigger mode;
“ON/OFF” ——under “Auto” mode it can control the lighting of lamp by pressing this button;
“DOWN” ——press it then the current will be reduced by 0.1A; under trigger mode it can also switch trigger mode;

Operation instructions

1. The xenon lamp is connected by a high-current connector, LAMP+ red wire connects anode of lamp, and LAMP- black wire connects cathode of lamp;(Wrong connection is forbidden.)
2. L, N connects 90~260V 50/60Hz AC, PE connects ground;
3. After connecting with electricity the screen will be lightened and the blower will rotate, under auto mode it will trigger the lamp after 2sec, then it will show the information like voltage current etc.
4. You can set the current and trigger model through the button “SET””UP””DOWN”
5.The xenon lamp off after the AC power off, the output current and trigger model is the same as last time when restart the AC power
6.Please set the power supply output current according to Short arc xenon lamp rated current.

Installation size

 

The dimension is L×W×H=265×157×82 (mm), can use M4 screw to install.

Notes

1. Pay more attention on the connection between LCX150 power supply and xenon lamp.
OUTPUT- Black cable connect xenon lamp” – “,OUTPUT+ Red cable connect xenon lamp”+”(forbid electrodepositive), avoid damaging the xenon lamp.
2. It needs wait 3minutes at least to turn on the lamp again;
3. Forbid cover LCX150 xenon power supply air vents and fan.
4. If LCX150 power supply install into a bigger case, guarantee cross-ventilation from inside and outside of the big case, keep good heat dissipation, high temperature will break the xenon power supply.
5、LCX450 power supply own open circuit protection function,the power supply will stop output when open circuit 3secs-5sces(or no connect xenon lamp)The power supply can return to normal work after turn on the power.

Request a Quote

Shandong Laser Source Technology Co.,Ltd
No.15 Lanxiang Road, Tianqiao Area, Jinan city 250032, Shandong China
Sale Hotline:                 0086-531-88190005
Technical Consultant: 0086-531-88190006
Production engineers:0086-531-58988699

CONTACT US